UPS-True Sine Wave Line Interactive
UPS - SPEC.
Click here
UPS - Uninterruptible Power Supply | |
■ ON Line - True Sine Wave | |
■ OFF Line - Square (Simulated) Sine Wave | |
■ Line Interactive True (Pure) Sine Wave | |
■ Line Interactive Square (Simulated) Sine Wave | |
■ DC UPS | |
■ Internal Disk UPS | |
■ Others | |
◆ E: sales@agstech.com.tw skype: glinda.tw |
Dual Input UPS, 1000VA / 600W, 1500VA / 900W, 2200VA / 1350W
Pure sine wave line interactive, true sine wave, on line UPS, 1KW UPS, 600VA UPS, 1500VA UPS, 5K UPS, off line UPS, made in Taiwan UPS, PSW inverter, true sine wave INVERTER, 1KVA inverter, 1000W Inverter, 1u UPS, disk UPS, internal UPS, 8KVA UPS, 12KVA UPS
Pure Sine Wave Line Interactive UPS | |||||||||
Professional long backup series | |||||||||
[if gte vml 1]>Bitmap | |||||||||
Quick charging when battery is not fully charged, trickle charging when battery is 90% fully charged. Charging current 11A at normal line and normal temperature (Average) Everage Batt. charging volt. Quick charging:14V max. / Trickle charging:13.2V ~13.9V adjustable by remote set-up software. Protection Over current protection & Over charging voltage protection (SCR control) Thermal protection (CPU control):When temperature inside UPS is over 45℃, charger will stop charging for 2.5 minutes followed by an 1.5 minutes charging. The cycle will be repeated until the temperature is lower than 44℃. Monitoring Smart monitoring & warning for failed battery or open-circuit battery. Auto-detection each time when power on or every 6 days. Communications & Management Standard Interface port UPSilon2000 compatible Standard RS232 & Optional USB Optional Interface port RJ45 (Surge Protection), DB9, SNMP Control panel LCD Audible alarm Alarm on battery:Low battery & Battery over voltage Alarm on abnormal operation:Over load, Short-circuit, & Over heat EBT (Estimation of Backup Time) Support for LCD display Green mode function 1% to 14% of full load (adjustable with the remote set-up software). The default setting is OFF. (Auto-shutdown during blackout) Cooling fan control Auto on / off, controlled by temperature & operation mode Environmental and Safety Operating Temp. Up to 1500 meters:0℃ to 40℃ (32℉ to 104℉) Transit/storage Temp. -15℃ to 55℃ (5℉ to 131℉) Relative Humidity 5 - 95% non condensing Operating Altitude 0 ~ 3000 meters Audible noise ≦50 dBA (at 1M from surface of unit) Isolation 1.5KVac for 1 minute between battery and AC side Physical 3000VA Dimensions: Machine 3u x 45cm DxHxW (cm) Package 59x33x59cm Weight: N.W. 29 (KGS) G.W. 33 Packing Export carton for each unit, 16 - 30 units per pallet * Specifications subject to change without prior notice.